Skip to content
EFLUXER

THE UNIT

Power on your site, with no connection to the grid.

A container that delivers 100 kW to 5 MW, day and night, with no grid connection, no fuel tank and no dependence on the weather. Below is what it delivers, what it does not need and how much room it takes.

20 ft or 40 ft · 100 kW to 5 MW · 363 running days

FROM ORDER TO POWER

  1. Within 80 days: it arrives

    EFLUXER comes by truck or trailer, like any container. Those 80 days include transport, and no construction work is needed.

  2. The same week: it runs

    Connect your machines and charging points and the power flows. No application to the grid operator, no queue, no connection charge.

  3. Project finished? It moves with you

    Lift it, drive it to the next site, connect it again.

SCALABLE

Start with one. Scale to a power park.

Each EFLUXER unit delivers 100 kW to 5 MW. Connect units in series and you have exactly the output you need, from a single construction site to multi-megawatt industry.

Total output
5 MW
Energy a year
43.800.000 kWh

Calculated at 8,760 running hours a year, so full output day and night. You set the output per module and the number of modules yourself above.

SPECIFICATIONS

Continuous output5 MW
Energy a year43,800,000 kWh
Voltage400 to 690 V
Frequency50 Hz
Operating temperature−20 °C to +40 °C
Housing20ft or 40ft standard container
TransportTruck or trailer
Lead timeMaximum 80 days, transport included
Planned maintenance2 days a year
DesignModular and scalable
RelocationMovable between projects

What this means in practice

  • Enough output for a large construction site, factory or data-intensive facility, around the clock.
  • Fits through any gate a truck can pass.
  • No permanent building permits: this is equipment, not a building.

WHERE THE UNIT DIFFERS

Four points you can check yourself.

EFLUXER does not win on everything, and pretending otherwise has no place here. On these four points the difference with solar, wind and a grid connection is measurable.

Land

Generating the same annual energy from solar panels takes 47.1 MWp of peak capacity. That is 47 to 72 hectares of solar farm. The container occupies 29.7 m² of ground.

Over 15,000 times less ground area

Running hours

In the Netherlands solar delivers the equivalent of 930 full-load hours a year, out of the 8,760 hours a year holds. That is 10.6%. The unit runs 8,712 of them and stops two days for planned maintenance.

99.5% of the year available

Grid connection

No application, no queue and no connection charge. In areas with grid congestion new large-user connections sit in a queue, and since 1 July 2026 that applies to small users too.

No waiting on the grid operator

Weather

No sun needed, no wind needed. Output in December at three in the morning is the same as in June at midday.

The same output, all year

Solar yield calculated at 930 kWh per kWp a year, the Dutch average for 2025. Land use at 0.65 to 1.00 MWp per hectare, the range used for utility-scale installations. Container dimensions per ISO 668. The output and running hours of the unit are supplied by the manufacturer.

LIFESPAN AND SERVICE

Forty years of power, watched day and night.

EFLUXER is built for a working life of 40 years. Planned maintenance takes two days a year, a major service every fourth year renews the unit, and remote monitoring follows it continuously.

  1. Year 1In service
  2. Every year2 days of service
  3. Every 4th yearMajor service
  4. 24/7Remote monitoring
  5. Year 40Still delivering

What does this mean for your budget?